Shakshat Virtual Lab
INDIAN INSTITUTE OF TECHNOLOGY GUWAHATI
Design of binary distillation column
- Theory
- Procedure
- Expt Calc
- Cost Calc
- Labview Calc
- Pre Expt Quiz
- Video
- Download
- Simulator
- Post Expt Quiz
DETAILS OF q-LINE :
TABLE 2.1
VALUE OF q |
SLOPE OF THE q-line (Equation 1) |
CONDITION OF FEED (Equation 2) |
0 | 0 i.e. Horizontal Line | Hf = hF , feed is a saturated vapor |
1 |
Infinite i.e. vertical line |
hF = hf , feed is a saturated liquid |
0-1 | -ve inclined between saturated liquid and saturated vapor line | Feed is a mixture of saturated vapor and saturated liquid |
>1 | +ve inclined beyond saturated q-line | hF < hf , feed is a liquid below the saturated liquid line |
<0 | +ve inclined below saturated vapor line | Feed is a superheated vapor |
FIG 2.3 LOCATION OF q-LINE FOR TYPICAL FEED COND ITIONS
.....................................equation 2.1
.....................................equation 2.2
NOMENCLATURE :
TABLE 2.2
Hf
|
Enthalpy of Vapor |
hF
|
Enthalpy of Feed |
hf
|
Enthalpy of Liquid |
xF
|
Mole Fraction of Feed |
xB
|
Mole Fraction of Bottom Product |
xD
|
Mole Fraction of Distillate |
R
|
Reflux Ratio |
The Basic difference between Design and Simulation of a Distillation Column is :
In Design | Given | alpha,xD,xB,xF,q and R |
Determine | NR, NS,Diameter and Cost | |
In Simulation | Given | alpha, NR, NS and xF |
Determine | xD, xB and R |