Shakshat Virtual Lab
INDIAN INSTITUTE OF TECHNOLOGY GUWAHATI
PROCEDURE :
Set the water bath temperature at desired level (25 0C- 50 0C) and wait till the bath attains the set temperature.
Fill the T- tube with carbon tetrachloride to within two centimeters of the top of Capillary leg . Note down the initial diffusion height of the liquid in the capillary from the top end (x0).
-
Make the connection with the air or vacuum pump and allow a gentle current of air to flow over the capillary.
-
Record the height of liquid (x) from the top of the capillary tube after every 30 mins.
-
Repeat the steps 1 to 4 for different temperatures.
-
Plot diffusion co-efficient against absolute temperature on a log - log graph and determine the slope. It should lie between 1.5 to 1.8.
SETUP DESCRIPTION :
The main components of the experimental setup are:
-
Glass T- Tube
-
Constant temperature water bath.
-
Air pump
-
Travelling Microscope
-
Volatile components is filled in the T- tube and air passed over it by the pump and change in the level is seen by the sliding microscope.
EXPERIMENTAL SETUP :
LEVEL OF CARBON TETRACHLORIDE AT T=0 |
LEVEL OF CARBON TETRACHLORIDE AT T=6 HRS |
The animation below describes the process :